Halfen Technical Manual
  Dynagrip Toothed Anchor Channels
  HALFEN Technical Manual
  Table of Contents
  Introduction
  Anchor Channels
  Page 09 Page 28
  Page 10 Page 29
  Page 11 Page 30
  Page 12 Page 31
  Page 13 Page 32
  Page 14 Page 33
  Page 15 Page 34
  Page 16 Page 35
  Page 17 Page 36
  Page 18 Page 37
  Page 19 Page 38
  Page 20 Page 39
  Page 21 Page 40
  Page 22 Page 41
  Page 23 Page 42
  Page 24 Page 43
  Page 25 Page 44
  Page 26 Page 45
  Page 27 Page 46
  Fasteners
  Channel Profiles
  Miscellaneous
 
 
 ANCHOR CHANNELS - Page 09 SiteMap Previous Page Next Page Printable Page
 
 
Halfen anchor channels are manufactured from channel profiles with 1-anchors shop-welded to the back of the channels.
 
They are available in ready-to-use short lengths and continuous lengths up to 20' - 0" (6.1m).  Custom lengths can also be manufactured to suit customer requirements.
 
Halfen anchor channels are available in hot dip galvanized carbon steel and are foam filled.  Stainless steel anchor channels are also available.
REINFORCEMENT  
Halfen anchor channels have been tested in unreinforced concrete and no additional reinforcing is normally needed to carry the published loads. However, the loads resisted by the anchor channels have to be transferred into the surrounding concrete and the engineer must ensure proper design of the complete system.
 
SAFETY FACTOR  
The loads shown in the catalog are working loads and include a safety factor of at least 3, applied to the ultimate strength of the anchor channel or surrounding concrete.
 
CONCRETE STRENGTH  
The load capacities of anchor channels shown are based on their performance in 3,000 psi (20.7 MPa) normal weight concrete. Some loads (marked *) are controlled by concrete strength and can be increased for  higher strength normal weight concrete, up to a maximum of 5,000 psi (34.5 MPa) by applying a factor of:
For light weight concrete strengths up to a maximum of 6,000 psi (41.4 MPa), apply a factor of:
 
MANUFACTURING TOLERANCES  
The dimensions shown are nominal. Tolerances of ± 1/8" (3mm) apply to lengths up to 12" (305mm) and ± 1/4" (6mm) on longer lengths.
 